• Description
  • Features
  • PTAC
  • Central A/C
  • RF Option
  • Wiring
  • Purchase
  • Read article
  • Contact



  •           


              HVAC Smart Relay Switch
     
          Energy management controller for heating,
    ventilation, and air conditioning systems!

    Go Green!
     HVAC Smart Relay Switch

    Reduce energy consumption in schools, hospitals, hotel rooms,
    apartments, condominiums, and more!



    Description

    In an era of high fuel costs, the HVAC Smart Relay Switch (HSRS) lowers energy bills by eliminating wasted power consumption.  The HSRS automatically interrupts the HVAC system in the event of a violation such as a door or window that has remained open for a period of time or a room that has been vacant.  The HSRS is a fully configurable relay device that provides energy efficient control for heating and cooling systems.  In addition, the HSRS can be used as a general purpose controller for devices including dampers, fans, etc.  The HSRS accepts one or more contact switch closures as control inputs.  Compatible with door/window reed switches, motion sensors, toggles, pushbuttons, etc., the HSRS can accept any switch or sensor device having normally open or normally closed contacts.  The HSRS is fully configurable using onboard DIP switches, allowing you to establish specific operational parameters.  For instance, configure the device to temporarily disable the air conditioning or heating system when any door or window has remained open for 10 minutes and then re-enable when the door has closed.  Onboard DIP switches allow you to configure operational mode and delay parameters. 

    The HSRS provides connections for as many as 4 wired inputs or zones.  Each input can accept a single switch sensor or multiple sensors if wired in a zone configuration (sensors are wired in series or parallel).  Typical switch sensors include reed switches, pushbuttons, toggle switches, or other devices.  (Note that the HSRS can be configured to accept either normally-open or normally-closed switches.)  Wired inputs are also compatible with TTL signals.

    And, with an optional RF receiver, the HSRS also accepts input from compatible wireless door/window sensors, motion detectors, and key fob transmitters.  The wireless option provides inputs for up to 10 additional devices.  Even deploy a combination of both wired and wireless sensors.

    The HSRS is the ideal energy management solution, reducing power consumption and energy costs.  Simply install door / window sensors and configure the controller with easy DIP switch settings. 

    HSRS is ideal for a number of venues including:

    • Hotels
    • Hospitals
    • Condominiums
    • Office complexes
    • Apartments
    • Schools
    • and more!

     Optional enclosure
    Optional enclosure




    Features:


         
    Interrupts (disables) HVAC when a violation is detected
    Can also be used with PTACs, window fans, dampers, etc.
    Fully programmable via DIP switch settings
    Configurable parameters including trigger polarity, LED mode, buzzer enable, etc.
    Selectable time delay ranging from 0 to 5 hours
    Five status LEDs:  system status plus switch sensor indicators
    Onboard relay: 10A @ 250VAC,  5A @ 100VDC
    Accepts wired inputs for monitoring up to 4 wired zones
    Optional RF receiver add-on for 10 wireless zones
    Configurable re-activate (relay on) and de-activate (relay off) delay periods
    DB9 interface for wireless RF receiver (for use with optional wireless sensors)
    DIP switches for mode selection & configuring operational parameters
    Selectable re-activate / de-activate time delays
    Terminal block connector for user wiring
    Powered by external 12VDC adapter (optional 24VAC adapter also available)
    Optional external power converter module accepts 24VAC for use with HVAC systems



    Application #1:  General Purpose (A/C, heater, damper, etc.)

    PTAC application



    Application #2:  Central Air Conditioning
    Central A/C


    Wireless RF Option

    For installations where traditional wire runs are not possible or may be inconvenient, we offer a wireless RF receiver add-on. 
    The receiver includes antenna and compatible interface for direct connection to the HSRS device for plug-and-play operation.  Available wireless peripherals include door / window sensors, motion detectors, key fob remote transmitters, etc.




    RF Receiver      
    Wireless door/window sensor
    RF Receiver + Antenna
    Wireless door / window sensor



    Wiring

    Customer wiring is performed using convenient screw terminals.   The table below lists the terminal connections:


    Terminal Description
    1 Input power (+12VDC)
    2 Ground
    3
    No connection
    4 Wired sensor #1
    5 Wired sensor #2
    6 Wired sensor #3
    7 Wired sensor #4
    8 Sensor return
    9 Sensor return
    10 Sensor return
    11 Sensor return
    12 Relay - COM
    13 Relay - N/C
    14 Relay - N/O